ABB TTH200 Head Mounted Temperature Transmitter
KSh 22065
ABB TTH200 Head Mounted Temperature Transmitter is a Head-mount temperature transmitter that supports both the HART 5 and HART 7 protocol and is the standard device of the proven two-wire technology. This temperature transducer is offered for all HART standard applications in temperature measurement with one (RTD or Thermocouple) sensor input.
Applications: Oil, Gas and Petrochemical, Research and Development, Hazardous Areas, etc.
ABB TTH200 Head Mounted Temperature Transmitter follows NAMUR Recommendations such as NE 89 and NE 107. This Temp Transmitter supports the functionality without sensor redundancy and sensor drift monitoring. An optional LCD indicator can be connected to understand the real-time measurement of temperature. It can be a perfect solution for industrial applications where temperature measurement will play a vital role in the process. In very sensitive locations like in cleanrooms & pharma companies, real-time monitoring of temperature helps them to make the right bioproducts like vaccines and medicines. This transmitter can be aligned with ABB tools such as Field Information Manager (FIM), with DAT200 (Asset Vision Basic) via DTM, with a Handheld via EDD, or with any standard tool using FDI-/FDT-Technology for better understanding of the measured parameter.
Features of ABB TTH200 Temperature Transducer :
• Universal sensor input
• RTD, thermocouple, Ω, mV
• Functional safety SIL 2 or SIL 3 in accordance with IEC 61508
• Various sensor error-calibration possibilities
• One point, two-point, Calendar-van Duson, freestyle characteristics with 32 supporting points
• Output signal
• 4 – 20 mA, HART 5 and HART 7 (switchable)
• Accuracy 0.1 %, long-term stability 0.05 % per year
• Wire break ( or ) corrosion monitoring in accordance with NE 89
• Event monitor for logging critical events
• Configuration monitor for configuration changes
• Turn able LCD indicator for optimal readability (option)
• Explosion protection Approvals : IECEx, ATEX, zone 0, FM / CSA, EAC, EAC-Ex, NEPSI
Additional information
Manufacturer | ABB |
---|---|
Model No | TTH 200 |
Input | Resistance RTD Pt-100, Thermocouples B,E, J, K, N, R,S, T, Voltages, mV Voltages |
Output | 4 to 20 mA; Configurable: 20 to 4 mA |
Cable Connection | Maximum sensor line resistance (RW) for each line: 1.5 kΩ, total: 3 kΩ |
Electrical Connection | Electrical connection Terminals (captive screws) incl. soldering tags |
Storage Temperature | -50 to 85 °C |
Ambient Temperature | Standard: -40 to 85°C; Optional: -50 to 85°C |
Voltage | −125 to 125 mV −125 to 1100 mV |
Electrical Interface | 3.5 kV DC (approx. 2.5 kV AC) 60 s, input to output |
Vibration Resistance | 10 to 2,000 Hz at 5g in acc. with IEC 60068-2-6, during operation and transport |
Input resistance | > 10 MΩ |
Display | Standard Supply Without Display |
Warm-up Time | 5 minutes |
Power Supply | 11 to 42 VDC |
Housing | Polycarbonate |
Communication | HART protocol |
Calibration | Provided alongwith and valid for 1 year, traceable to National Standards. |
Weight | 50 Grams |