Hello!

Click on our representative below to chat on WhatsApp or send us an email to [email protected]

×

Ace AI-CRM1-1 Hospital Operation Theatre Monitor

In stock

Ace AI-CRM1-1 Hospital Operation Theatre Monitor will live vital parameters like Temperature, ratio, Differential Pressure with associate inbuilt alarm for any setpoint violation. clean room Monitor Model AI-CRM1-1 is designed for simple flush mounting into wall panels and brick walls of clean area with clean minimum cabling.

Applications: Hospitals, Pharma Clean Rooms, biotechnology, HVAC, Blood banks, etc.

Ace AI-CRM1-1 Hospital Operation Theatre Monitor includes the sensors for Temperature, Relative Humidity, Differential Pressure incorporated for ease to use and installation. The combination of humidity & temperature sensor is flushed to the front stainless-steel plate and the differential pressure is built-in with hose nipple connections at the rear for +ve and -ve pressure connections.
Features of Ace Hospital Operation Theatre Monitor:

  •  Integrated buzzer for parameter violation alert
  •  Different LED for process violation visual alert
  • RS 485 Modbus Communication for easy integration to BMS/SCADA/EMS
  • Provision to integrate with IoT module for real-time monitoring and alerts.

Additional information

Manufacturer

Ace Instruments

Model No

AI-CRM1-1

Measuring Parameters

Differential Pressure, Relative Humidity and Temperature

Pressure Range

0 to 10.0 mm. W.C./ 0 to 100 Pascals

Accuracy

±0.5% of Full Scale

Resolution

0.1 mm.W.C. / 1 Pascals

Temperature Range

0 to 50°C

Humidity Range

0 to 100% RH

Accuracy

±1.8% for 10 to 95% RH

Resolution

0.1% R.H

Display

3 Line Red 7 segment LED display of Height 0.8”, 3 Digits for Differential Pressure on line 1, 3 Digits for Temperature (Deg.C) on line 2, 3 Digits for % R.H. (Humidity) on line 3

Differential Pressure Entry

2 Nos. 4 mm. Hose Nipples at top of clean room monitor enclosure

Sensor Type

1) Polymer sensing for Temperature 2) Capacitive polymer sensing for Relative humidity 3) Piezo Resistive Sensor for Differential Pressure

Setting

By 4 keys on the front stainless steel panel

Buzzer

Integrated buzzer for Alarm Hi & Lo in case of process violation of any of the 3 parameters

Power Supply

24VDC, 250mA

Communication

RS 485 Modbus RTU protocol communication for BMS / SCADA / PLC integration.

Mounting

Wall Mounting / Modular Wall mounting with Stainless Steel Front Flush Plate for Clean Rooms

Enclosure

M.S. Powder coated body with stainless steel front plate for Modular wall mounting/ optional brick wall mounting

Compliance

Multilevel password protection as per USFDA 21 CFR part 11 specification

Warranty

1 Year Manufacturer's Warranty

Calibration

Provided alongwith and valid for 1 year, traceable to National Standards.

Dimensions

Front Stainless Plate : 200(H) x 180 (W) mm, MS Powdered Back Box :140 (W) x 150 (H) x 35 (D) mm

Weight

600 Grams

Be the first to review “Ace AI-CRM1-1 Hospital Operation Theatre Monitor”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Name Download
DS_AI-CRM1-1_Clean_Room_Monitor_With_Internal_Sensor_Ver-1.01

Main Menu

Ace AI-CRM1-1 Hospital Operation Theatre Monitor

Ace AI-CRM1-1 Hospital Operation Theatre Monitor